Material Safety Data Sheet
CLEAN MAL 05
Material Identification and Use
| Manufacturer's Name | NOCO Energy Corp. |
| Manufacturer's Address | 2440 Sheridan Dr., Tonawanda, NY 14150 |
| Emergency Phone Number | 1-800-424-9300 (Chemtrec) |
| Supplier's Address | P.O. Box 86, Tonawanda, NY 14151 |
| Supplier Emergency Phone Number | 1-800-500-6626 |
| Product Name | Clean Mal 05 |
| Product Code | NOC5305 |
| Chemical Name and Synonym | N/A |
| Product Use | A high performance, mild alkaline liquid cleaner concentrate designed to be diluted with water for a variety of industrial cleaning applications. |
Ingredients
| Components | Percentage | CAS Number | Hazard Data |
| Dipropylene Glycol Methyl Ether | 1 - 5 | 34590-94-8 | OSHA PEL/TWA 100 ppm (mist)
ACGIH TLV/TWA 100 ppm (mist) ACGIH STEL/TWA 150 ppm (mist) |
| Proprietary Additive | 95 - 99 | Proprietary | None as defined by OSHA 29 CFR 1910.1200 |
| WHMIS Classification | Not Controlled. |
Physical Data
| Physical State | Liquid |
| Odour and Appearance | Sweet Odor, Blue Clear Liquid |
| Specific Gravity | 1.037 |
| Vapor Pressure (MM HG @ 20° C) | < 20 |
| Vapour Density | < 1.0 |
| Evaporation Rate | Not Determined |
| Boiling Point | Approx. 215°F (100°C) |
| Freezing Point | N/A |
| pH | 9.5 +/- .3 @ 20:1 |
| Solubility in H20 | Complete |
Fire and Explosion Hazards
| Conditions of Flammability | Won't Burn |
| Extinguishing Media | None |
| Flashpoint and Method of Determination | None |
| Flammable Limits in Air % B. V. Upper | None |
| Flammable Limits in Air % B. V. Lower | None |
| NFPA - Hazard Class | Health:1 Fire:0 Reactivity:0 |
| Hazardous Combustion Products | Won't Burn |
| Unusual Fire an Explosion Hazard | Won't Burn |
| Special Fire Fighting Procedures | Won't Burn |
Reactivity Data
| Chemical Stability | Stable |
| Incompatible Materials | Strong oxidizing agents: Peroxides, Chlorine, Strong Acids, etc. |
| Hazardous Decomposition | Small amounts of C, N |
| Hazardous Polymerization | Material is not known to polymerize. |
Health Hazard Information
| Routes of Entry | |
| Skin Contact | Prolonged or repeated contact with skin may cause mild irritation and possibly dermatitis. |
| Eye | Can be irritating to eyes. |
| Inhalation | May cause respiratory tract irritation. |
| Ingestion | May cause vomiting and headaches and may cause irritation to mucous membranes. |
| Carcinogenicity | Not carcinogenic. |
Emergency and First Aid Procedures
| Eyes | In case of contact, flush eyes with large amounts of water for at least 15 minutes. Get medical attention. |
| Skin | Wash skin thoroughly with soap and water or waterless hand cleaner. If irritation occurs, get medical attention. |
| Inhalation | If breathing is difficult, remove victim to fresh air, give artificial respiration if not breathing. |
| Ingestion | Do not ingest. If ingested, give milk or water. Get medical attention. |
Preventative Measures
| Ventilation Requirements | Use explosion proof ventilation as required to control vapor concentration. |
| Respiratory Protection | Not required under normal OSHA TLV. Use NIOSH approved respirators to prevent over-exposure. |
| Eye Protection | Safety glasses with side shields or goggles. |
| Protective Gloves | Nitrile gloves provide best protection to hands and arms. |
| Personal Hygiene | Wear effective plant clothing. Contaminated clothing should be removed and washed in soap and water. Cleanse skin thoroughly before meals with soap and water. Shower and eyewash facilities should be accessible. |
| Note | N/A |
Environmental Procedures
| Spills or Releases | If material is spilled or released to the atmosphere, steps should be taken to prevent discharges to streams or sewer systems. Spills or releases should be reported, if required to the appropriate local, state and federal regulatory agencies. |
| Disposal | Clean up action should be carefully planned and executed. Shipment, storage and/or disposal of waste materials are regulated and action to handle or dispose of spilled or released materials must meet all state, local, and federal rules. |
| Storage | Protect against physical damage. Separate from oxidizing materials. Store in cool well ventilated area of non-combustible construction away from possible sources of ignition. |
Regulatory Information
| Dept. of Transportation | DOT Shipping Name: NONE
Hazard Class: NONE ID Number: NONE |
| TSCA | All Components are Listed on EPA/TSCA Inventory. |
| CERCLA | None |
| RCRA | If this product becomes a waste it would not be a hazardous waste by RCRA - 40 CFR 261. Place in an appropriate disposal facility in compliance with local authorities. |
| SARA Title III - Section 302 | Not Applicable |
| Section 311/312 | Not Applicable |
| Section 313 | Not Applicable |
Preparation Date of Material Safety Data Sheet
| Prepared By | NOCO - Tom Scoda |
| Phone number of Preparer | 1-800-229-6626 |
| Date Prepared | 06/29/2000 |
| Revised Date | 06/01/2008 |
Disclaimer
| Information presented herein has been compiled from information provided to us by our suppliers and other sources considered to be dependable and is accurate and reliable to the best of our knowledge. Nothing herein is to be construed as recommending any practice or the use of any product in violation of any patent or in violation of any law or regulation. It is the users' responsibility to determine the suitability of any material for a specific purpose and to adopt such safety precautions as may be necessary. We make no warranty as to the results to be obtained in using any material and since conditions of use are not under our control, we must necessarily disclaim all liability with respect to the use of any material supplied by us. |