Material Identification and Use
|
Manufacturer's Name |
|
|
Manufacturer's Address |
2440 Sheridan Dr., Tonawanda, NY 14150 (U.S. and Canada) |
|
Emergency Phone Number |
1-800-424-9300 (Chemtrec) |
|
Supplier's Address |
P.O. Box 86, Tonawanda, NY 14151 |
|
Supplier Emergency Phone Number |
1-800-500-6626 |
|
Product Name |
NOCOLUBE ZINC FREE AW HYDRAULIC OILS |
|
Product Code |
NOC |
|
Chemical Name and Synonym |
Petroleum Hydrocarbon plus Additives |
|
Product Use |
Premium Zinc-free AW hydraulic oils. |
Chemical Ingredients
|
Product Components |
CAS Number |
% (Volume) |
|
Paraffin Base Oils |
See below |
> 99% |
The Base Oil may contain one or more of the following ingredients: 61788-76-9, 64741-88-4, 64742-01-4, 64742-65-0, 64742-89-5, 64742-48-9, 64742-52-5, 64742-54-7, 64742-56-3.
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.
Physical Properties
|
Form |
Liquid |
|
Appearance |
Liquid |
|
Odor |
Bland |
|
Color |
Amber |
|
Relative Density |
0.86 @ 15.6 ⁰ C |
|
Flash Point Boiling Point |
203°C (398°F), COC > 330°C (625°F) |
|
Melting Point |
< -26°C (-15°F) |
|
Solubility in Water (by weight %) |
0 at 20°C |
|
Evaporation Rate |
0 |
|
Vapor Pressure |
<0.13 kPa (<1 mm Hg) |
|
pH (as is) |
Not Applicable |
|
Stability |
Product is stable under normal conditions |
Fire and Explosion Hazards
|
Conditions of Flammability |
Addition of water or foam may cause frothing. Do not cut, drill or weld empty containers. |
|
Extinguishing Media |
Foam, Water Fog, Dry Chemical, Carbon Dioxide. Closed containers exposed to fire may be cooled with water. |
|
Flashpoint and Method of Determination |
148°C (298.4°F) , COC |
|
Flammable Limits in Air % B. V. Upper |
Not Determined |
|
Flammable Limits in Air % B. V. Lower |
Not Determined |
|
NFPA - Hazard Class |
Health:1 Fire:1 Reactivity:0 |
|
Hazardous Combustion Products |
From Burning; carbon monoxide, carbon dioxide and oxides of phosphorous. |
|
Unusual Fire an Explosion Hazard |
Do not cut, weld, braze, solder, drill, grind or expose containers, drums, tanks,etc. of product to heat, flame, sparks, static electricity or other sources of ignition; they may ignite explosively. |
|
Special Fire Fighting Procedures |
Wear self contained breathing apparatus (SCBA) when fire fighting with full face piece operated in pressure mode. Do not use water except as fog. |
Reactivity Data
|
Chemical Stability |
Stable |
|
Incompatible Materials |
Keep away from strong oxidizing agents, such as, hydrogen peroxide, Bromine, chlorine and chomic acid. |
|
Hazardous Decomposition |
Hazardous decomposition products should not be produced under normal conditions of storage and use. |
|
Hazardous Polymerization |
Material is not known to polymerize under normal conditions of storage and use. |
Health Hazard Information
|
Routes of Entry |
|
|
Skin Contact |
Prolonged or repeated contact with skin may cause mild irritation and possibly dermatitis. |
|
Eye |
Mildly irritating to eyes. |
|
Inhalation |
If heated, sprayed or misted, may cause chemical pneumontis. |
|
Ingestion |
Low toxicity on ingestion. Has laxative effect. |
|
Carcinogenicity |
Not listed as a carcinogenic. |
|
Health Hazard Data |
Permissible
Concentrations (air): See COMMENTS section |
Emergency and First Aid Procedures
|
Eyes |
Check for and remove contact lenses. In case of contact, flush eyes with large amounts of water for at least 15 minutes. Get medical attention if symptoms occur. |
|
Skin |
Remove excess with cloth or paper. Wash skin thoroughly with soap and water or waterless hand cleaner. If irritation occurs, get medical attention. |
|
Inhalation |
If breathing is difficult, remove victim to fresh air, give artificial respiration if not breathing. Call a physician. |
|
Ingestion |
Do not ingest. If ingested, do not induce vomiting. Contact a physician immediately. |
Special Protection / Preventative Measures Information
|
Ventilation Requirements |
No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. Use explosion proof ventilation as required to control vapor concentration. See COMMENTS section. |
|
Respiratory Protection |
If vapor concentration exceeds permissible exposure use NIOSH / MSHA certified respirator with dual organic vapor, mist and particulates cartridge. |
|
Eye Protection |
Safety glasses with side shields or goggles. (Chemical safety goggles) |
|
Protective Gloves |
Neoprene or natural rubber (latex) type |
|
Personal Hygiene |
Wear effective plant clothing. Contaminated clothing should be removed and washed in soap and water. Cleanse skin thoroughly with soap and water after handling chemical products, before meals, smoking or using the lavatory and at the end of the working period. Shower and eyewash facilities should be accessible. |
|
Protective Equipment |
None |
|
HMIS Code/Personal protective equipment |
B |
Environmental Procedures
|
Spills or Releases |
If material is spilled or released to the atmosphere, steps should be taken to prevent discharges to streams or sewer systems. Transfer bulk of mixture into another container. Absorb residue with inert material such as earth, sand, or vermiculate. Sweep up and dispose as solid waste in accordance with local, state, and federal regulations. Spills or releases should be reported, if required to the appropriate local, state and federal regulatory agencies. |
|
Disposal |
Clean up action should be carefully planned and executed. Shipment, storage and/or disposal of waste materials are regulated and action to handle or dispose of spilled or released materials must meet all state, local, and federal rules. |
|
Storage Handling |
Store in accordance with local regulations. Store in original container and keep container tightly closed and sealed until ready for use. Store in cool well ventilated area of non-combustible construction away from possible sources of ignition. Protect against physical damage. Separate from oxidizing materials. Do not handle or store at temperatures over (maximum storage temperature) 60°C (140°F). Do not store in unlabeled containers. Wear appropriate personal handling equipment (see Special Protection/Preventative Measures Information section). Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands before eating drinking and smoking. Do not breathe vapor or mist. Do not ingest. Avoid contact with eyes, skin and clothing. Keep in original container or an approved alternative made from a compatible material, kept tightly closed when not in use. |
Regulatory Information
|
Dept. of Transportation |
DOT
Shipping Name: NONE |
|
TSCA |
All Components are Listed on EPA/TSCA Inventory. |
|
CERCLA |
This product is classified as an oil under section 311. Spills into or leading to surface water that cause sheen must be reported to the National Response Center at 1-800-424-8802. |
|
RCRA |
If this product becomes a waste it would not be a hazardous waste by RCRA - 40 CFR 261. Place in an appropriate disposal facility in compliance with local authorities. |
|
SARA Title III - Section 302 |
Not Applicable |
|
Section 311/312 |
Not Applicable |
|
Section 313 |
This product does not contain any chemical in sufficient quantity to be subject to the reporting requirements of Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 and 40 CFR Part 372. |
|
Reportable Quantity |
Not Applicable |
|
Freight Classification |
Petroleum Lubricating Oil |
Comments
|
If used in applications where a mist may be generated, observe a TWA/PEL of 5 mg/m3 for mineral oil mist (OSHA and ACGIH). All components of this product are on the US TSCA Inventory and Canadian Domestic Substance List. The additive manufacturers have declared the additive mixtures in this product a trade secret. |
Preparation Date of Material Safety Data Sheet
|
Prepared By |
Chuck Rapelje |
|
Phone number of Preparer |
1-800-500-6626 |
|
Date Prepared |
10/01/2010 |
Disclaimer
|
We believe the statements, technical information and recommendations contained herein are reliable, but they are given without warranty or guarantee of any kind, express or implied, and we assume no responsibility for an loss, damage, or expense, direct or consequential, arising out of their use. |