Material Safety Data Sheet

BIOCOOL SERIES   (100, 105 EP) and BIOCOOL 100 (Undyed)


Material Identification and Use


Manufacturer's Name NOCO Energy Corp., Inc.
Manufacturer's Address 2440 Sheridan Dr., Tonawanda, NY 14150
Emergency Phone Number 1-800-424-9300 (Chemtrec)
Supplier's Address P.O. Box 86, Tonawanda, NY  14151
Supplier Emergency Phone Number 1-800-500-6626
Product Name and Code

Biocool 100 (undyed) NOC0874
Biocool 100 NOC0875
Biocool 105 EP NOC0876

Chemical Name and Synonym N/A
Product Use Semi-synthetic Metalworking Fluid

Ingredients


Components Percentage CAS Number Hazard Data




Mineral Oil 15 - 20 64742-52-5 OSHA PEL/TWA 5mg/m3 (mist)
ACGIH TLV/TWA 10mg/m3 (mist)




Dipropylene Glycol Methyl Ether 0 - 3 34590-94-8 OSHA PEL/TWA 100ppm
ACGIH TLV/TWA 100ppm
ACGIH STEL/TWA 150ppm




WHMIS Classification

D2B

Physical Data


Physical State Liquid
Odour and Appearance Clear Green/Amber Liquid, Bland Odor
Specific Gravity 1.015
Vapor Pressure (MM HG @ 20° C) < 0.1 
Vapour Density > 1.0
Evaporation Rate Not Established
Boiling Point 100°C  (215°F)
Freezing Point 35°F (1°C)
pH 9.2 ± .3  (5% in water)
Solubility in H20 Complete

Fire and Explosion Hazards


Conditions of Flammability Will not burn.
Extinguishing Media Will not burn.
Flashpoint and Method of Determination None
Flammable Limits in Air % B. V. Upper Not Determined
Flammable Limits in Air % B. V. Lower Not Determined
NFPA - Hazard Class Health:1  Fire:0  Reactivity:0
Hazardous Combustion Products Asphyxiants
Unusual Fire an Explosion Hazard None Known
Special Fire Fighting Procedures Wear self contained breathing apparatus when fire fighting in a confined space. Cool fire exposed containers with water spray.

Reactivity Data


Chemical Stability Stable
Incompatible Materials Avoid contact with strong oxidizers, heat, strong acids and bases. 
Hazardous Decomposition Asphyxiants
Hazardous Polymerization Material is not known to polymerize.

Health Hazard Information


Routes of Entry
Skin Contact Prolonged or repeated contact with skin may cause mild irritation.
Eye May cause eyes to burn or cause eye irritation.
Inhalation Mist or vapors exceed TLV. Oil mist can cause mild irritation of respiratory tract.
Ingestion Vomiting could occur, due to irritation of digestive tract.
Carcinogenicity No known carcinogens according to ACGIH, OSHA and NTP.

Emergency and First Aid Procedures


Eyes In case of contact, flush eyes with large amounts of water for at least 15 minutes. Get medical attention.
Skin Wash skin thoroughly with soap and water or waterless hand cleaner. If irritation occurs, get medical attention.
Inhalation If breathing is difficult, remove victim to fresh air, give artificial respiration if not breathing.
Ingestion Do not ingest. If ingested, do not induce vomiting. Get medical attention.

Preventative Measures


Ventilation Requirements No special requirements under normal use. Local ventilation is adequate.
Respiratory Protection Not required under normal use. If concentrations exceed OSHA PEL use NIOSH approved respirators.
Eye Protection Safety glasses with side shields or goggles.
Protective Gloves Nitrile gloves provide best protection to hands and arms.
Personal Hygiene Wear effective plant clothing. Contaminated clothing should be removed and washed in soap and water. Cleanse skin thoroughly before meals with soap and water. Shower and eyewash facilities should be accessible.
Note N/A

Environmental Procedures


Spills or Releases If material is spilled or released to the atmosphere, steps should be taken to prevent discharges to streams or sewer systems.  Spills or releases should be reported, if required to the appropriate local, state and federal regulatory agencies.
Disposal Clean up action should be carefully planned and executed. Shipment, storage and/or disposal of waste materials are regulated and action to handle or dispose of spilled or released materials must meet all state, local, and federal rules.
Storage Protect against physical damage. Separate from oxidizing materials. Store in cool well ventilated area of non-combustible construction away from possible sources of ignition.

Regulatory Information


Dept. of Transportation DOT Shipping Name:  NONE 
Hazard Class:  NONE 
ID Number:  NONE
TSCA All Components are Listed on EPA/TSCA Inventory.
CERCLA This product is classified as an oil under section 311.  Spills into or leading to surface water that cause sheen must be reported to the National Response Center at 1-800-424-8802.
RCRA If this product becomes a waste it would not be a hazardous waste by RCRA - 40  CFR 261.  Place in an appropriate disposal facility in compliance with local authorities.
SARA Title III - Section 302 Not Applicable
Section 311/312 Not Applicable
Section 313 Not Applicable

Preparation Date of Material Safety Data Sheet


Prepared By NOCO - Tom Scoda
Phone number of Preparer 1-800-500-6626
Date Prepared 07/19/2000
Revised Date 07/23/2014

Disclaimer


Information presented herein has been compiled from information provided to us by our suppliers and other sources considered to be dependable and is accurate and reliable to the best of our knowledge. Nothing herein is to be construed as recommending any practice or the use of any product in violation of any patent or in violation of any law or regulation. It is the users' responsibility to determine the suitability of any material for a specific purpose and to adopt such safety precautions as may be necessary. We make no warranty as to the results to be obtained in using any material and since conditions of use are not under our control, we must necessarily disclaim all liability with respect to the use of any material supplied by us.